Condensation and damp glossary

The words surveyors, installers and building guidance use, explained in plain English.

Absolute humidity
The actual amount of water vapour in the air, usually in grams per cubic metre (g/m³). Unlike relative humidity, it doesn't change when air warms or cools, so it's the right way to compare indoor and outdoor air.
Air brick
A perforated brick that ventilates a suspended timber floor void or an old fireplace. Blocking air bricks can lead to damp and timber decay.
Air changes per hour (ACH)
How many times the air in a room is replaced with outdoor air each hour. Higher rates remove moisture faster but lose more heat.
Condensation
Water vapour turning to liquid when air cools to its dew point, usually on a cold surface. See what causes condensation.
Cavity wall
Two layers of masonry with a gap between them, common in UK homes built from the 1920s–30s onwards. The cavity may be empty or filled with insulation.
Damp-proof course (DPC)
A waterproof layer built into a wall just above ground level to stop moisture rising from the ground. Bridging it — with high paths, soil or render — can cause low-level damp.
Desiccant dehumidifier
A dehumidifier that absorbs moisture with a drying material rather than a cold coil. It works better than compressor models in cold rooms but usually uses more power.
Dew point
The temperature at which air becomes saturated and water starts to condense. Any surface colder than the dew point of the room air gets wet. Try our dew point calculator.
dMEV (decentralised mechanical extract ventilation)
Quiet extractor fans that run continuously at low speed in wet rooms and boost when needed.
fRsi (temperature factor)
A number from 0 to 1 describing how close an inside surface stays to room temperature. 1 is as warm as the room; 0 is as cold as outside. UK guidance recommends at least 0.75 at junctions in homes to limit mould risk. See thermal bridges.
Hygrometer
A device that measures relative humidity, usually alongside temperature. Loggers record readings over time.
Hygroscopic salts
Salts left in old plaster and masonry (from groundwater, chimneys or past damp) that absorb moisture from the air, keeping walls damp-looking even after the original cause is fixed.
Interstitial condensation
Condensation that forms inside a wall, roof or floor, where warm moist air meets a cold layer. It's hidden, so it's prevented through design — vapour control layers and breathable materials — rather than spotted.
Mould
Fungi that grow on surfaces kept at high humidity — around 80% or more for long periods. Visible black or grey spots are usually condensation-related. See black mould.
MVHR (mechanical ventilation with heat recovery)
A whole-house system that extracts stale, moist air, supplies fresh air, and transfers heat between them so less warmth is lost.
PIV (positive input ventilation)
A fan unit, often in the loft, that gently pushes filtered air into the home, displacing moist air through gaps and vents. See ventilation explained.
Rain penetration
Water entering a building from outside through defects such as blocked gutters, cracked render, failed pointing or window seals. It needs repair, not condensation control.
Relative humidity (RH)
How much water vapour air holds compared with the maximum it could hold at that temperature, as a percentage. The same air reads a higher RH when cooled and lower when warmed. See ideal humidity.
Rising damp
Groundwater drawn up through masonry by capillary action. It exists but is often misdiagnosed; low-level damp has several other common causes.
Sealed unit
The double- or triple-glazed glass panel in a window frame. Misting between the panes means its seal has failed.
Solid wall
A wall with no cavity, typically brick or stone, common in homes built before about 1920. Usually colder on the inside than a filled cavity wall.
Thermal bridge
A spot where heat escapes faster than through the surrounding structure — corners, lintels, junctions — leaving a colder inside surface prone to mould.
Trickle vent
A small adjustable slot, usually in the top of a window frame, providing constant background ventilation. Best left open.
U-value
How quickly heat passes through a wall, window or roof, in W/m²K. Lower is better insulated — and gives a warmer inside surface.
Vapour control layer
A membrane on the warm side of insulation that limits moisture moving into the structure, preventing interstitial condensation.